SpectraMax iD3 and iD5 Multi-Mode Microplate Readers
Personalisasi berbasis NFC dan alur kerja layar sentuh yang ditingkatkan menyediakan kemudahan penggunaan tanpa perlu penyesuaian khusus. Pembaca Mikroplat Multi-Mode SpectraMax® iD3 dan iD5 mengukur absorbsi, fluoresensi, dan luminesensi. Selain itu, pembaca iD5 mengukur TRF dan FP dan dapat diperluas untuk mencakup TR-FRET, HTRF®, BRET, pengujian laporan luciferase ganda dengan injektor, dan deteksi blot barat.
Baca Selengkapnya Minta Penawaran Video ProdukSpesifikasi SpectraMax iD3 and iD5 Multi-Mode Microplate Readers
Read modes | Absorbance Fluorescence (top/bottom read) Luminescence (top read) |
Absorbance Fluorescence (top/bottom read) Luminescence (top/bottom read) Time-Resolved Fluorescence (top/bottom read) Fluorescence Polarization (top/bottom read) HTRF (top/bottom read) HTRF |
Wavelength ranges | Abs: 230 - 1000 nm FL Ex: 250 - 830 nm FL Em: 270 - 850 nm Lumi: 300 - 850 nm |
Abs: 230 - 1000 nm FL Ex: 250 - 830 nm FL Em: 270 - 850 nm Lumi: 300 - 850 nm TRF Ex: 350 nm TRF Em: 450 - 750 nm FP: 300 - 750 nm |
Wavelength selection | Monochromator tunable in 1-nm increments | Hybrid filters and monochromator tunable in 1 nm increments |
Absorbance photometric accuracy/linearity | < ±0.010 OD ±1.0%, 0 - 3 OD VIS 0 - 3 OD UV | < ±0.010 OD ±1.0%, 0 - 3 OD VIS 0 - 3 OD UV |
Absorbance photometric precision/repeatability | < ±0.003 OD ±1.0%, 0 - 3 OD VIS 0 - 3 OD UV | < ±0.003 OD ±1.0%, 0 - 3 OD VIS 0 - 3 OD UV |
Sensitivity top read optimized | FL: 1 pM fluoresein 96 well, 1 pM fluorescein 384 well Lumi: 2 pM ATP 96 well, 4 pM |
FL: Mono: 1 pM fluorescein 96 well, 1 pM fluorescein 384 well; Filters: 0.3 pM fluoresein 96 well, 0.5 pM fluorescein 384 well Lumi: 2 pM ATP 96 well, 4 pM ATP 384 well TRF (filters with enhanced TRF module): 10 fM Europium (2 amol/well) 96 well, 10 fM Europium (1 amol/well) 384 well FP: Mono: 2 mP @ 10nM 96 well, 2 mP @ 10nM 384 well; Filters: 1 mP @ 1 nM 96 well, 2 mP @ 1 nM 384 well |
Light source(s) | High power xenon flash lamp | High power xenon flash lamp |
Detector(s) | Silicon photodiode Ultra-cooled photomultiplier tube | Silicon photodiode Ultra-cooled photomultiplier tube |
Read types (endpoint, kinetic, etc) | Endpoint Kinetic Spectrum scan Well scan | Endpoint Kinetic Spectrum scan Well scan |
Read times | Abs: 28 seconds FL: 21 seconds Lumi: 21 seconds | Abs: 28 seconds FL: 21 seconds Lumi: 21 seconds TRF: 25 seconds FP: 35 seconds |
Plate shaking | Linear Orbital Double orbital | Linear Orbital Double orbital |
Injectors | YES | YES |
Western blot | No | YES |
Stand-alone touchscreen operation | Yes | Yes |
Robotics / automation | Yes | Yes |
Plate type(s) | 6-384 well plates | 6-384 well plates |
Temperature control | Ambient + 5°C to 66°C | Ambient + 5°C to 66°C |
Dimensions | H 40.1 cm x W 53.2 cm x D 59.8 cm | H 40.1 cm x W 53.2 cm x D 59.8 cm |
Validation tools | Absorbance validation plate Fluorescence validation plate Luminescence validation plate SoftMax® Pro GxP Software |
Absorbance validation plate Fluorescence validation plate Luminescence validation plate Multi-mode validation plate SoftMax® Pro GxP Software |