Produk data dan gambar MACSQuant® Tyto® Cell Sorter

Full sterility Samples are kept contamination-free within the disposable, fully closed MACSQuant Tyto Cartridge. No risk for carry-over or contamination of fluidics.

Fast and easy handling No drop delay or laser alignment needed. Simply insert the cartridge, gate on cells, and sort.

Gentle to cells Sort and even re.sort cells under low pressure without compromising cell viability or functionality. Cells are no longer exposed to high pressure, charge, or decompression.

Spesifikasi MACSQuant® Tyto® Cell Sorter

MACSQuant Tyto technical specifications

Optic

Laser excitation 405 nm, 100 mW
  488 nm, 100 mW
  638 nm, 100 mW
Emission detectors V1: 450/50 nm
  V2: 525/50 nm
  B1: 525/50 nm
  B2: 585/40 nm
  B3: 655–730 nm
  B4: 750 nm LP
  R1: 655–730 nm
  R2: 750 nm LP
  Backscatter and side scatter for detection of size & granularity of cells
Fluorescence performance 5 decade logarithmic scales, display in lin, log, or hlog scales
   

 

Performance

Purity >99%*
Cell flow rate Up to 55,000 cells/s for the MACSQuant Tyto Cartridge and up to 110,000 cells/s
for the MACSQuant Tyto Cartridge HS  
Sort rate Up to 30,000 valve actuations/s
Viability >99% for lymphocytes*
Sorting mode Two-way sorting of sorted and non-sorted cells
Technical support Built-in live support functionality for reliable support in real time
Operating pressure <230 mbar (3 psi) with the MACSQuant Tyto Cartridge and 1100 mbar (<14 psi)
  with the MACSQuant Tyto Cartridge HS
Temperature control range 4–25 °C (under standard environmental conditions)
Carry-over No sample-to-sample carry-over due to single-use disposable cartridge

 

Data management

Measurement parameters Height & Area measurements for all parameters
Signal processing 16-bit analog-to-digital conversion and signal processing
Operating system Core i7, 512 GB flash disk, 8 GB DDR4 RAM and Windows® 7 64-bit
Compensation Full 8×8 matrix compensation
Data files .mqd (proprietary file type); fcs (2.0, 3.0, 3.1 compatible)

 

Operation details

Dimensions 965 × 585 × 280 mm3: without external monitor
  965 × 585 × 760 mm3: with external monitor
Weight 62 kg (137 lbs): without external monitor
  67 kg (148 lbs): with external monitor
Monitors 32 ̎ display and 15.6 ̎ touchscreen (internal)
Power requirements / consumption 100-240 V, 50/60 Hz / 300 W: without external monitor
  100-240 V, 50/60 Hz / 500 W: with external monitor
Ports 4× USB 2.0, 6× USB 3.0, 2× Ethernet, DVI-D

 

Environmental conditions

Operational temperature / humidity 18–25 °C / 0–85% relative humidity, non-condensating
Emission sound pressure < 70 dB(A) level at workstation <70 dB(A)

 

Cartridge details

Sterility Ethylene oxide-validated sterilization method to guarantee sterility of each cartridge
A-septic filters 0.1 µm hydrophobic filters at air inlet and outlet ports
Sorting channel width 25 × 50 µm
Maximum loading volume (input) 100 µL–10 mL
Maximum loading cell number 5×107 cells/mL
Cartridge alignment for laser positioning Continuous automated cartridge alignment also during the sort
Cell retrieval No cell loss - negatively sorted cells are kept in the negative collection chamber
Barcode labeling Cartridges are labeled with a barcode for easy identification and traceability